R410a pressures at 90 degrees

Jun 25, 2020 ... 90K. Subscribe ... How To Add Refrigerant To Your Air Conditioner R410A & R22 ... Really High Head Pressure and Coil Looked Clean!

R410a pressures at 90 degrees. What Should be the Pressure of R410a Refrigerant in Air ConditionerFull Detail Of R410a Gas pressure running pressure information of R410aStanding Pressure I...

pressure of about 250 psi at an outdoor temperature of 95°F. With R-410A, the same unit will operate under the same conditions with a suction pressure of 118 psi and a discharge pressure of 400 psi, as shown in Figure 1 on the next page. (Note that in most cases, equipment designed for R-22 cannot use R-410A because of this difference in operating

Residential 410a system as follows: Liquid line: ~400psi. ~ 30 subcool. Vapor line: 105psi. ~30 superheat. The LLFD does not feel cold. The TXV is backed all the way out. Critical Pressure 4926.1 kPa (abs) (714.50 psia) Critical Density 3488.90 kg/m3 (30.52 lb/ft ) Critical Volume 30.00205 m /kg (0.0328 ft3/lb) Units and Factors t = Temperature in °C T = Temperature in K = °C + 273.15 P = Absolute Pressure in KiloPascals (kPa [abs]) v f = Volume of saturated liquid in m3/kg v g = Volume of saturated vapor in m3/kg (View the Pressure Temperature Chart pictured below for reference) Again, say you have a low side pressure of 76 psi on a HVAC system containing R-22 refrigerant, view the pressure temperature chart and find 76 psi and follow it across to the R-22 column. The evaporator saturation temperature on the chart, reads 45 degrees Fahrenheit.The normal pressure for a typical R-401A mini-split ranges from 110-140 psi. However, keep in mind that the working pressure depends on factors like cooling load and weather. According to experts, the working pressure should never be less than 100 psi or more than 160 psi.If the condenser saturation pressure for an R-22 system is 226.4 psig and the condenser outlet temperature is 90 degrees, what is the condenser subcooling? a. 110 degrees b. 90 degrees c. 20 degrees d. 10 degrees . Show transcribed … The low side pressure of a typical R410A mini split is between 110-140 psi depending on the operating conditions. Though it can vary, the low side pressure of a mini split should not fall below 100 psi or raise beyond 160 psi. The working pressure of mini splits is depending on factors such as the weather and cooling load. Temp. Temp. Temp. Temp. Temp. Temp. Temp. Temp. ( F) Liquid Vapor ( C) ( F) Liquid Vapor ( C) ( F) Liquid Vapor ( C) ( F) Liquid Vapor ( C)-49 5.5 5.4 -45.0 1 49.7 49.5 -17.2 51 145.8 145.2 10.6 101 323.1 322.1 38.3-48 6.0 5.9 -44.4 2 51.1 50.8 -16.7 52 148.4 147.9 11.1 102 327.7 326.7 38.9

So we replace the compressor (same model #), replace the liquid line filter dryer, and evacuate to 500 microns. I weigh the charge in per the manual = unit's orignal charge + addl ounces per foot of lineset - total of 5# 6 oz. Start unit up, damn it, looks wrong immediatelY: Suction: 149.5 psi. Suction Temp: 55.4*F.Jun 25, 2016 · The liquid pressure should be 385-395 and the suction pressure should be about 138 but will probably be a few psi lower since it's so cool in the space. The sub-cool should be 11 deg. F +/- 1.5 deg. F. The pressure gauges for this refrigerant stays between 22 PSI and 57 PSI (pounds per square inch). But you have to keep in mind that there are two different sides to this chart. And you have to consider the low as well as the high side. Hence, the normal low-pressure side for R 134a needs to be less than 90 degrees.Feb 14, 2024 · The operating pressure of 410a on an 85 degree day is 254.6 psig. Example 3: What are 410a pressures on a 70 degree day? The operating pressure of 410a on a 70 degree day is 201.5 psig. fi 410A Refrigerant (R-410A) ... (488.90 kg/m3) Critical Volume 0.0328 ft3/lb (0.00205 m3/kg) Units and Factors t = temperature in °F ... Because both pressure and temperature appear in the reduced form in the equation, the same …

Sin 90 degrees is equal to one. This degree value can also be expressed in radians as sin(?/2) = 1. This value of the sine function corresponds to one-fourth of the complete arc di...Nov 16, 2020 · The low-side should be near 30 PSI at 90 degrees Fahrenheit or less. Pressure that is too much lower or higher shows there is a problem. On a properly working system, high-side pressure will be about twice the ambient temperature, plus 50 PSI. What pressure should 410A be at 80 degrees? R-410A Pressure Temperature Chart. PSIG(Pounds per Square Inch Gauge) R-410A (HFC) °Fahrenheit; 78: 20: 80: 21: 85: 24: 90: 26: What is the pressure of R-410A at 72 degrees Fahrenheit? 208,4 psig Example: What is the pressure of r410a at 72 degrees Fahrenheit? We can see …R410A R410A 01 23.0 6.5 02 27.5 7.8 03 2) 34.0 9.8 Technical data and ordering: TCBE Thermostatic expansion valves – TUB/TUBE/TCBE Ordering TCBE, straightway, thermostatic expansion valve with bulb strap R410A Refrigerant Type Rated capacity 2) Ori˜ce no. Pressure equalisation Code no. Connection inlet × outlet in. × in. Range N –40/+10 ...

Kappa alpha psi charges.

Quickly calculate Superheat, and Subcooling measurements for R22 & R410A refrigerants. R410A R22. Outdoor Temp . Indoor Temp . Suction PSI *Required. Liquid Line PSI *Required. Suction Line Temp *Required. Liquid Line Temp *Required. Calculate. Would you like to create a proposal for a new lead? ...Nov 16, 2020 · The low-side should be near 30 PSI at 90 degrees Fahrenheit or less. Pressure that is too much lower or higher shows there is a problem. On a properly working system, high-side pressure will be about twice the ambient temperature, plus 50 PSI. The cosine (cos) of 90 degrees is zero. This value is taken from the unit circle, a commonly used device in mathematics that assigns values to the trigonometric functions of sine a...410a pressure. I installed a 410a, 2 ton condenser and coil today. The low side was 120 with 10 degree super heat, just like the manufacturer recommendations, but the high side was 475psi with 40 degree of subcooling. I felt like 475psi on a 80 degree outdoor temp was really high. Delta T was 14 indoor and the indoor wet bulb was 64degree.Typical Low Side Pressure Range for R410A in the field: 115-120 psi. Typical High Side Pressure Range for R410A in the field: 410-420 psi. By 2025, high Global Warming Potential (GWP) refrigerants with a GWP of over 750, will be banned together with the systems using that gas. R410A has a GWP > 2,000.An online theology degree can open the door to deeper spiritual understanding and a greater recognition of the role of religion in society. Written by TheBestSchools.org Staff Cont...

Most of you know R-32 as a necessary component in the widely popular HFC blend known as R-410A Puron. R-32 along with R-125 gets you that R-410A that is found in nearly every air conditioner today. However, in recent years there has been a push to slowly phase down R-410A. That is because of 410A’s very high Global Warming Potential, or GWP.Temperature and pressure chart for refrigerants R22, R410A, R12, R134A, R401A, R409A, R502, R404A, R507A, R408A and R402A. Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications! 404R pressure temperature chart is quite simple to understand. This is a table that tells you precisely what the pressure of R404A is at a certain temperature. At the low end, the pressure of 404A is 0.9 psig. At the high end, the pressure of 404A is 456.8 psig. We are, of course, talking about 404A liquid pressure. R410A Pressure Temperature Chart R410A Temperature (°C) Pressure (barA) Pressure (barg) Pressure (psig) Pressure (barA) Pressure (barg) Pressure (psig)-70 0.36 -0.66 -9.52 0.35 -0.66 -9.55-68 0.40 -0.61 -8.85 0.40 -0.61 -8.87-66 0.45 -0.56 -8.10 0.45 -0.56 -8.13-64 0.51 -0.50 -7.27 0.51 -0.50 -7.31-62 0.57 -0.44 -6.37 0.57 -0.44 -6.40 Measurement points (Table 1) consisted of temperatures, pressures, pressure difference, temperature difference, dew-point temperature, and power. Refrigerant properties were obtained from REFPROP 6.0 (McLinden et al. 1998). Table 1 lists measured and calculated quantities Table 1: Measurement uncertainty at 95 % confidence levelTypical Low Side Pressure Range for R410A in the field: 115-120 psi. Typical High Side Pressure Range for R410A in the field: 410-420 psi. By 2025, high Global Warming Potential (GWP) refrigerants with a GWP of over 750, will be banned together with the systems using that gas. R410A has a GWP > 2,000.Transforming objects in Adobe Illustrator so they appear angled -- like the difference between a rectangle and a parallelogram, which lacks the rectangle's uniform 90-degree corner...Transforming objects in Adobe Illustrator so they appear angled -- like the difference between a rectangle and a parallelogram, which lacks the rectangle's uniform 90-degree corner... R410A has a GWP > 2,000. Measuring the refrigerant pressure in air conditioning, heat pump or other refrigerant systems can diagnose a range of operating problems including a refrigerant leak, over charging or under charging.

Adult male rats were received corn oil or DBP injection intraperitoneally (ip) at 100 and 500 mg/kg body weight on 90, 97, 104, and 111 days. Following ...

Adult male rats were received corn oil or DBP injection intraperitoneally (ip) at 100 and 500 mg/kg body weight on 90, 97, 104, and 111 days. Following ...It worked good until Saturday. It was not cooling the house. 90 deg outside. Temp got up to 78 inside while set on 72. It would normally maintain 72 no problem. Air at vents was still 60 degrees and had good air flow going through new filter and blowing out vents, but house was still not cooling. Unit was making a funny noise.Temperature Calculator. This script determines the gas pressure based on temperature of R410a refrigerant.I am charging my heat pump it is an r410a and its about 90 degrees outside i have gotten the low side up from about 100psi to 130 and the high side from around 300psi to 340-50 is this about right what should my pressures be. The 410a part of the gauge is reading 44 low and 106 for high.(R-508B) is a better replacement than Freon™ 410A. Properties Freon™ 410A is safe to use when proper storage and handling practices are followed. It is a nonflammable, low toxicity mixture of HFC-32 and HFC-125 (50/50 wt%). Freon™ 410A has been classified as A1 by ASHRAE and assigned the ASHRAE number of R-410A. It has been 75 80 85 90 95 100 105 110 115 Cooling Pressure (PSI) @ Service Port (Tolerance +/‐5) Outdoor Temp (°F) Refrigerant Pressure vs. Temperature Charts for Pioneer Split Systems (R410a) 68 115 119 123 127 131 135 139 143 147 71 120 124 128 132 136 140 144 148 152 ‐ m p (°F) 74 125 129 133 137 141 145 149 153 157 Jun 24, 2018 ... ... 90 degree attachment https://amzn.to/2MMtVcg ... HVAC Pressure Testing Procedure for Air Conditioners! ... What Should my AC Pressures Be for R410A ...

Erie county judicial tax sale.

Lee's meats screven ga.

146. Post Likes. R410a isn't ineffective above 90 degrees. But R410a loses both capacity and efficiency faster than R22 as the temperature rises. According to this study, R410a is better at lower temperatures and R22 is better at higher temperatures. The breakeven point is around 90°F-95°F.A "90 days same as cash" deal lets you leave a retailer's store with your purchase and without parting with any money. But there's a catch. You must pay off the cost within three m...and a temperature sensor, and externally by the system high and low pressure switches. • Reliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. • Environmentally friendly - CFC-free R-410A refrigerant delivers environmentally friendly performance with zero ozone depletion.R-410A at 80 degrees F, in the absence of non-condensables, will be pressurized to: 237 psig. To change the evaporator on a system containing. R-410A, you must: Recover the refrigerant to atmospheric pressure and hold for a few minutes. If the system pressure does not rise, remove the evaporator.R410A is a blend of two hydrofluorocarbon (HFC) refrigerants: R32 and R125. These two components work together to create a refrigerant with excellent thermodynamic properties. R32 provides high energy efficiency, while R125 contributes to the stability and heat transfer performance of R410A. When it comes to the chemical …Pressure (psig) Temp (°C) Liquid Vapor Liquid Vapor Liquid Vapor Liquid Vapor ... -10 36,5 36,3 -23,3 40 118,8 118,4 4,4 90 275,4 274,5 32,2 140 542,5 541,4 60 ...A "90 days same as cash" deal lets you leave a retailer's store with your purchase and without parting with any money. But there's a catch. You must pay off the cost within three m...Most of you know R-32 as a necessary component in the widely popular HFC blend known as R-410A Puron. R-32 along with R-125 gets you that R-410A that is found in nearly every air conditioner today. However, in recent years there has been a push to slowly phase down R-410A. That is because of 410A’s very high Global Warming …When operated at a 35 degC ambient temperature, the suction pressure of an Air-Conditioner with R410A refrigerants ranges from 115 to 125 Psig. At these operating conditions, the discharge pressure is around 400 Psig. R-410A operates at 50 to 70% higher pressures than the R-22. Last updated: 19 days ago – 12 co-authors – 9 users.The operating pressure of 410a on an 85 degree day is 254.6 psig. Example 3: What are 410a pressures on a 70 degree day? The operating pressure of 410a on a 70 degree day is 201.5 psig. ….

Jul 22, 2022 ... I work on r410a system(txv) today! My head pressure run 425 psig with 0 subcooling and my low side ( back pressure) only run 105 psig my ...R-410A, sold under the trademarked names AZ-20, EcoFluor R410, Forane 410A, Genetron R410A, Puron, and Suva 410A, is a zeotropic but near-azeotropic mixture of difluoromethane (CH 2 F 2, called R-32) and pentafluoroethane (CHF 2 CF 3, called R-125) that is used as a refrigerant in air conditioning and heat pump applications. R-410A …What pressure should 410A be at 80 degrees? R-410A Pressure Temperature Chart. PSIG(Pounds per Square Inch Gauge) R-410A (HFC) °Fahrenheit; 78: 20: 80: 21: 85: 24: 90: 26: What is the pressure of R-410A at 72 degrees Fahrenheit? 208,4 psig Example: What is the pressure of r410a at 72 degrees Fahrenheit? We can see … R410a pressure chart high and low side. Temp(°F) Liquid Pressure (psi) Vapor Pressure (psi) -49. 5.5. 5.4. -48. 6.0. Below we list a dozen causes of high head pressure in an air conditioner or heat pump compressor motor. Of these, debris clogging or malfunctioning TXVs seem to be the most common problems. Air contamination in the …Critical Density 3488.90 kg/m3 (30.52 lb/ft ) Critical Volume 30.00205 m /kg (0.0328 ft3/lb) Units and Factors t = Temperature in °C T = Temperature in K = °C + 273.15 P = Absolute Pressure in KiloPascals (kPa [abs]) v f = Volume of saturated liquid in m3/kg v g = Volume of saturated vapor in m3/kg V = Volume of superheated vapor in m3/kg d f ... 404R pressure temperature chart is quite simple to understand. This is a table that tells you precisely what the pressure of R404A is at a certain temperature. At the low end, the pressure of 404A is 0.9 psig. At the high end, the pressure of 404A is 456.8 psig. We are, of course, talking about 404A liquid pressure. I have a 3 ton condenser. my low side pressure is 85psi/50 degree temp., high side is 415psi/156 degree temp., its r-22 system my wet bulb is 71 degrees, my air temp. at the condenser is 98 degrees,temp. is 72 degrees at the vapor line. that gives me the propper subcooling but the pressures and temps. are too high. 415psi is too high so is ... 4 Using Table 2, select the column which is closest to the measured vapor pressure. 5 Scroll down the column to find your calculated superheat. 6 Read the required vapor line temperature at the intersection. (°F) If the measured vapor line temperature does not agree with the required vapor line. 7 temperature, add refrigerant to lower ... R410a pressures at 90 degrees, 410a ductless mini split operating pressures. I know that you should rarely put gauges on a ductless mini split, and that you should dump the charge and just weigh it in. I have heard that there are spec sheets that will give you "normal operating pressures" based on indoor and outdoor conditions. This would come in handy when servicing …, An online theology degree can open the door to deeper spiritual understanding and a greater recognition of the role of religion in society. Written by TheBestSchools.org Staff Cont..., The low side pressure of a typical R410A mini split is between 110-140 psi depending on the operating conditions. Though it can vary, the low side pressure of a mini split should not fall below 100 psi or raise beyond 160 psi. The working pressure of mini splits is depending on factors such as the weather and cooling load., R410A Pressure Enthalpy Chart. Download a PDF copy of the pressure enthalpy chart for both Metric and Imperial Units. By. Paul Evans - Apr 14, 2019. 2. Facebook. Twitter. Pinterest. WhatsApp. R410A Pressure Enthalpy Chart. Scroll down to download a PDF copy of the pressure enthalpy chart for both Metric and Imperial Units., Subcooling is a measurement of temperature DECREASE of a liquid below its saturation (mixed liquid/vapor) temperature at a given pressure. For example, water boils at 212° Fahrenheit at sea level (atmospheric pressure of 14.7 PSIA). If water is 212°F and at atmospheric pressure at sea level, you can be sure it is at saturation, which means it ..., Saturation Pressure-Temperature Data for R410A (psig)*. ECLPC-1 Rev 1 – 02/22., Which statement about R-410A is true. Mixtures of R-410A with air can become combustible, never mix R-410A with air or oxygen for either leak testing or pressurizing a system. A recovery cylinder which is half full of recovered R-410A at 80 degrees F, in the absence of non-condensables, will be pressurized to: 237 psig., How to calculate R-410A subcooling? Alright, let’s take a 3.5-ton 18 SEER unit, attach the gauge and thermometer. We measure that the temperature of the saturated refrigerant is 95°F (via pressure and referencing R-410A PT chart) and the thermometer tells us that the subcooled R-410A liquid temperature is 87°F. Let’s calculate R-410A ..., What are the ordinary static pressures that you all are used to for a 410A unit on a 65 degree day? I'm working on a York condenser that went out on Low Pressure weeks ago. I topped her off with a few pounds of 410A and now it trips on High Pressure, but I was confident in my original charge because of the pressures/temps I observed at the time., This is a pressure-temperature chart that specifies the saturation pressure for R410A at any given temperature. The R410A PT chart can be used to answer questions like: What are normal operating pressures for 410A? What is the pressure of r410a at 72 degrees Fahrenheit? What should gauge read for 410A?, Pressure/Temperature Chart. You must identify your local store and sign in to see local price and availability information and place orders. Johnstone Supply is a leading wholesale distributor for HVACR equipment, parts and supplies available and in-stock at local branches., Pressure-Temp Chart-40-35-30-25-20-15-10-5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 11.6 14.9 18.5 22.5 26.9 31.7 36.8 42.5 48.6 55.2 62.3 70.0 78.3 87.3 96.8 107 118 130 142 155 170 185 201 217 235 254 274 295 317 340 365 391 418 446 476 507 539 573 608 Physical Properties of ..., Refrigerants - Physical Properties. 1) Production of R11 or CFC-11 was halted by the clean air act on January 1, 1996. 2) Production of R12 or CFC-12 (Dichlorodifluoromethane) was halted by the clean air act on January 1, 1996. 3) R22 or HCFC-22 is a single component HCFC refrigerant with low ozone depletion potential., Jan 3, 2024 · How to Read an R-410A PT Chart. 1. Identify Desired Temperature. Determine Temperature: Choose the required temperature for your system based on its application or specific needs. 2. Find Corresponding Pressure. Locate on Chart: Find the selected temperature on the P-T chart and note the corresponding pressure in psig (pounds per square inch ... , (View the Pressure Temperature Chart pictured below for reference) Again, say you have a low side pressure of 76 psi on a HVAC system containing R-22 refrigerant, view the pressure temperature chart and find 76 psi and follow it across to the R-22 column. The evaporator saturation temperature on the chart, reads 45 degrees Fahrenheit., If two lines are perpendicular to the same line, they are parallel to each other and will never intersect. Advertisement Welders and carpenters use all sorts of tools to set things..., Online R454B pressure temperature chart spanning from -40°F to 150°F temp. Printable PDF version of R454B PT chart you can take with you on the job. There are several brand names for R454B: Opteon XL41, Solstice 454B, and Puron Advance. This is a blend of R32 (68.9%) and R1234yf (31.1%). It has a very low boiling point of -59.5°F (-50.9°C)., TEMPERATURE - PRESSURE CHART FOR R-22, R-410A, R-407C, R-134A & R-404A REFRIGERANTS FYI #289 9/17/2009. updated 10/10/2012. Data points are reproduced based on available information. Advantage assumes no responsibility or liabililty for data errors. ADVANTAGE Engineering, Inc. 525 East Stop 18 Road Greenwood, IN 46142 …, With the right music degree, you could be on the way to your dream job in the music business. Updated May 23, 2023 thebestschools.org is an advertising-supported site. Featured or ..., From the PT chart, we can read that the pressure of liquid 448a on a 90-degree day is 208.4 psig. Similarly, we can see that the vapor pressure of 448a on a 90-degree is 181.2 psig. Example 7: What Are 448a Pressures On A 95-Degree Day? From the PT chart, we can read that the pressure of liquid 448a on a 95-degree day is 224.4 psig., When operated at a 35 degC ambient temperature, the suction pressure of an Air-Conditioner with R410A refrigerants ranges from 115 to 125 Psig. At these operating conditions, the discharge pressure is around 400 Psig. R-410A operates at 50 to 70% higher pressures than the R-22. Last updated: 19 days ago – 12 co-authors – 9 users., Adult male rats were received corn oil or DBP injection intraperitoneally (ip) at 100 and 500 mg/kg body weight on 90, 97, 104, and 111 days. Following ..., R22 changes from a liquid to a gas in the evaporator coils of the air handler. Normal temperatures: With compressor running and as reference, on a 90 degree F. day: - Goodman runs 45degrees F on low pressure side and 115degrees F on high pressure side. - 2 ton York runs 40degrees F on low pressure side and 110degrees F on high pressure side. , Numbering scheme. According to ASHRAE standard 34, the R-number of a chemical refrigerant is assigned systematically according to its molecular structure and has between two and four digits. If there are carbon-carbon multiple bonds, there are four digits in all: the number of these bonds is the first digit and the number of carbon atoms minus one (C-1) …, I am wondering what the high and low pressures should be in a 3-ton 410a refrigerant AC system. The installer seemed very unsure of himself. It was 88 or 90 degrees F (and humid outside) and he ended up setting (leaving?) the pressures at 142 psi on the low side and 350 on the high side. He said something about a 200 psi difference being normal., 1. Outdoor ambient temperature 2. Typical low pressure or suction side pressure for R410A is about 120 psi, varying by ambient temperature, here assuming 75°F, may vary by equipment and metering controls 3. Typical high side pressure for R410A is < 600 psi at an ambient outdoor temperature of 95 °F, may vary by equipment 4. barA. Known as " …, Head on 410 at 100° will be in the 375 - 400 range depending on surrounding conditions, sun, heat load inside, dirt on the coil. high suction pressure could be from a high load, bad compressor, bad-wrong-nonexistant metering device. There are a multitude of things that can cause pressures to be high or low depending on the situation., Pressure Temperature Charts Vapor Pressure in PSIG °F °C R-410A 60 15.6 170 65 18.3 185 70 21.1 201 75 23.9 217 80 26.7 235 85 29.4 254 90 32.2 274 95 35.0 295 100 37.8 317 105 40.6 340 110 43.3 365 115 46.1 391 120 48.9 418 125 51.7 446 130 54.4 476 ... R-410A R-32 (50%), R-125 (50%) Difluoromethane, Pentafluoroethane -61.0°F., Temperature Calculator. This script determines the gas pressure based on temperature of R410a refrigerant., fi 410A Refrigerant (R-410A) ... (488.90 kg/m3) Critical Volume 0.0328 ft3/lb (0.00205 m3/kg) Units and Factors t = temperature in °F ... Because both pressure and temperature appear in the reduced form in the equation, the same …, , Pressure-Temp Chart-40-35-30-25-20-15-10-5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 11.6 14.9 18.5 22.5 26.9 31.7 36.8 42.5 48.6 55.2 62.3 70.0 78.3 87.3 96.8 107 118 130 142 155 170 185 201 217 235 254 274 295 317 340 365 391 418 446 476 507 539 573 608 Physical Properties of ... , The chart displays temperature values (in degrees Fahrenheit or Celsius) against pressure values (in pounds per square inch gauge, or PSIG), allowing for …