Eg4 6500ex inverter

The 6000EX-48HV is a residential self-consumption, multi-functional true split phase inverter/charger. Combining the capabilities of an inverter, MPPT solar charger, and a battery charger, the 6000EX-48HV offers uninterrupted power support in a single package. Upgraded features, when compared to the competition, include a 500VOC/7500W max input ...

Eg4 6500ex inverter. SKU: EG4-18KPV-12LV. Spec Sheet Manual Certification. Specifications: 18,000W PV input. 12,000W AC continuous output. Stackable – Parallel multiple units together. Closed loop communication with EG4 & SOK SK48V100 batteries. Overload, short circuit, and over temperature protection. 120/240V split phase output with line balancing.

4.4 36 reviews Ing. Enrique Butty 275 Capital Federal Buenos Aires, C1001AFA. Welcoming members across a range of industries, our Torre Catalinas office space delivers a sought-after address and unparalleled amenities amidst the irrefutable allure of Buenos Aires. Two floors of beautifully designed lounges, conference rooms, and private offices ...

Oct 26, 2023. #1. Most of us have probably seen Will’s review of the new EG4 6000xp by LuxPower. However, I have a few questions that weren’t quite clear to me. While the unit has surge capacity to 12kw, he said something about no surge capability on one leg only. While in use two 6500ex units now, one unit has the ability to surge well ...I am also planning to do a firmware update but want to avoid the issues everyone else is experiencing. I had 1-6500ex 48 RMA'd through SS a year ago and that one is running 79.60 the other is 61.06. They keep changing settings periodically. ... I have two EG4 6500 EX inverters that have been working very well in parallel for the past 6 months. ...The EG4 6000EX-48HV inverter does not list the idle consumption in any of it's documentation, and now I see that's probably because it consumes a lot! About 130 watts idle consumption for this unit. For comparison, a 4448 Magnum inverter consumes about 25 watts at idle and the OutBack 8048GSA consumes about 34 watts at idle.I had purchased the LV6548's before the EG4 6500EX's but moved my array farther away (420 feet one way) and wanted a higher VOC rated inverter. Original firmware in the LV6548's. I do not use the LV6548's charge controllers. I added a pair of EG4 MPPT100-48 SCC's due to higher string voltage.I am in the middle of doing a split phase set up with 2 EG4 6500EX patterned off Will Prowse YT video released on May 25, 2022. My question is specific to his load center diagram. ... Split Phase v2 3000 EG4 Inverters - Poor Ground. girfold; May 29, 2023; Beginners Corner; Replies 5 Views 407. Oct 17, 2023. CavemanPrevia. C. J. EG4 6500EX ...

The EG4 6500 EX-48 is a residential self-consumption, multi-functional inverter/charger. Combining the capabilities of an inverter, MPPT solar charger, and battery charger, the 6500EX-48 All-in-One Solar Inverter offers uninterrupted power support in a single package. Upgraded features compared to the competition include a 500VOC/8000W max ...Then turn on your other batteries one by one letting each one initialize before you move to the next battery. If your inverter does not come on, then press the power button one time and wait for the countdown to complete and for it to initiate. Then press the return button on the inverter. You want to select EG4.17. Nov 8, 2022. #1. I saw someone had a post on the 120 circuit flickering of lights. It worse with the LED bulbs but noticeable on incandescent and halogen types. I doesn't mater if I'm running on solar, battery or utility. My thought is that the inverter is putting out these blips. It can happen once in while or a couple times a second.Feb 18, 2023. #12. self_sufficient_25 said: Buyers beware, I purchased a pair of 6500EX-48 eg4 inverters on December 15 2022, I just got around to testing them, 2 weeks ago, I was greatly disappointed to find the off grid idle power, in battery only mode to be 100-110w way over the rated <70w advertised.The EG4 6500 EX-48 is a residential self-consumption, multi-functional inverter/charger. Combining the capabilities of an inverter, MPPT solar charger, and battery charger, the 6500EX-48 All-in-One Solar Inverter offers uninterrupted power support in a single package. Upgraded features compared to the competition include a 500VOC/8000W …

EG4 6500EX auto start generator. Thread starter mikeyoungvcu89; Start date Jan 18, 2023; M. mikeyoungvcu89 New Member. Joined Jul 5, 2022 Messages 44. ... Turned the inverter back off. Generator resumed charging. Left it charging and the generator ran for 3.7 hours and charged the system up to 53.5 rather than the set point of 56.EG4-WallMount Indoor Battery 280AH | 51.2V | 14.3kWh & EG4 6000XP Off-Grid Inverter Bundle 8000W PV Input | 6000W Output | All-In-One Solar Inverter [BNDL-E0009] The WallMount Indoor 280Ah batteries are ideal for low-voltage residential indoor energy storage ap. $5,412.00. $4,978.00.Ben I have a EG4 6500EX from Signature Solar and has been working great for 3 months since I first hooked it up, but a couple days ago it quit and gave F09 code. Tried restarting and same thing. ... EG4 6500ex-48 All in One Inverter/Charger for sale. zach541; Oct 13, 2023; Inverters and All-in-One Units For Sale; Replies 5 Views 657. Jan 9, 2024.As the time period is shortened SA regurgitates AC output data that more precisely matches what the inverter's display spits out in the videos. The 24-hour period gives a better visual of how the issue progressively worsens through the day. Six EG4 LP4. USE, 55.5 float, 56.5 absorb.Today I'm working on one of the final pieces of my 48v installation of the EG4 6500EX Inverters, which is hooking up the grid to the AC input. While I alrea...Inverter EG4 6500EX-48 User Manual. Solar inverter/charger 6.5kva 120v ac (75 pages) Inverter EG4 6000EX-48 User Manual. Inverter / charger (53 pages) ... Page 11: Mounting The Inverter EG4 Electronics EG4 Electronics www.eg4electronics.com www.eg4electronics.com Before connecting all wirings, please take off bottom cover by removing the five ...

Section 101 allstate arena.

I never programmed the Modus interface for the EG4-6500EX by myself (I've only studied the Modbus spec of the EG4-6500EX). I just use SA to do the Modbus communication with the inverters and batteries. My smart home (OpenHAB) communicates via MQTT with SA and SA converts these MQTT messages to Modbus protocol.However, It turns out that EG4 started shipping all of their inverters without the bonding screw. ... EG4 6500ex and 6000ex flickering lights and firmware. EG4_Jarrett; Oct 31, 2023; Off-grid Inverters; 4 5 6. Replies 109 Views 6K. Feb 23, 2024. BobbyB. B. EG4 6000ex unexpected grid surge. wildbillpdx;View and Download EG4 6500 EX-48 user manual online. SOLAR INVERTER/CHARGER 6.5KVA 120Vac. 6500 EX-48 inverter pdf manual download. Sign In Upload. Download Table of Contents Contents. Add …As per the instructions, I connect my phone to the wifi module of the inverter. This seems to work. Then it asks for the log in info for my local wireless network. I enter the info and the screen says " success wifi kit rebooting " and then there is a 9 sec clock that counts down.

Grounding and Bonding for MPP LV6548 and EG4 6500EX-48. Click on the orange download button above to get the document. This document shows how to handle grounding and bonding with the MPP LV6548 and EG4 6500EX-48 Warning 1) EG4 requires explicit permission from the distributer before removing the... diysolarforum.com.Edit Aug 29, 22. Just got off phone with tech support and they tell me they have a new software update almost ready for release that should revolve the Error...I am just setting up 2 EG4-6500EX-48's with a single Trophy 100Ah battery, and solar assistant on the way. I have them wired up, 5 400 watt panels to each inverter. Again this is just a test setup and is off-grid. I ran a load test to drain the battery which it did. The inverter setting #29 at 48.0, which is Trophy's suggested and the highest ...May 6, 2023 · I am just setting up 2 EG4-6500EX-48's with a single Trophy 100Ah battery, and solar assistant on the way. I have them wired up, 5 400 watt panels to each inverter. Again this is just a test setup and is off-grid. I ran a load test to drain the battery which it did. The inverter setting #29 at 48.0, which is Trophy's suggested and the highest ... Newbie jere. Just finished installing my first starter system. 6500ex with two 52v Lifepower batteries. Relatively small pv setup at the moment, 8 x 210W panels in series. I'm metering 128v at the mc4 connectors before PV dc disconnect at the panel. The reading im getting from the inverter display for PV input is around 50v and extremely low ...The EG4 6500 EX-48 is a residential self consumption, multi-functional inverter/ charger, combining the capabilities of an inverter, MPPT solar charger, and a battery charger to offer uninterupted power support in. a single package. The comprehensive LCD display offers user configurable and easily-accessible button operation including: battery ...May 30, 2022 · 1) Install 500-600W PV panels totaling 8kW-9kW. 2) Split-phase Inverter (s) - I really like the Sol-Ark 15k because it seems to meet all of my needs, but is expensive. 3) 6 - LiFePower4 Batteries (to start) 4) Stay connected to grid. 5) Add a DC generator to charge batteries as a failsafe in the event of extended bad weather. Signature SolarIn today’s fast-paced world, convenience is key. That’s why kitchen appliances have evolved to make our lives easier and more efficient. One such innovation is the inverter microwa... EG4® 3000EHV-48 All-In-One Off-Grid Inverter. 5kW Solar Input | 3kW AC Output. 48V Battery Compatible. Learn More.

Yeah, on mine the eg4 setting had 56v bulk and 56v float. The battery status on the display never read accurately even when the voltage reading was good. The "scale" was just off and using the inverter values to monitor on Solar Assistant battery values was no good. Ended up using user ant assigning 56v for bulk and 54.8 for float.

Eg4 6500ex vs ecoworthy 5000w inverters self battery wake up. I have installed both of these units and the units that I have struggled the most is eg4 6500ex. Ecoworthy 5kw once left unintended. If the battery end up sleeping when lifepo4 battery detect low charge voltage, the unit will wake it up once there's solar or program to charge with grid.40 amp breaker in main panel supplies grid to inverter. 40 amp breaker in inverter output, then to sub-panel. sub-panel breakers connect to house loads. nuetral and ground from sub-panel to main panel. confirmed N-G bond exists only in main panel. PS: The inverter ran for a week with no fault codes without grid power connected.I am in the middle of doing a split phase set up with 2 EG4 6500EX patterned off Will Prowse YT video released on May 25, 2022. My question is specific to his load center diagram. ... Split Phase v2 3000 EG4 Inverters - Poor Ground. girfold; May 29, 2023; Beginners Corner; Replies 5 Views 407. Oct 17, 2023. CavemanPrevia. C. J. EG4 6500EX ...The EG4 6500ex and 6000ex both make use of a similar mppt grounding configuration. So the screw will help with both inverters. If the inverter already has the screw present, firmware has been updated to 79.71, and there isn't multiple bonds in the same installation, then at that point, I'd some different light bulbs.Edit Aug 29, 22. Just got off phone with tech support and they tell me they have a new software update almost ready for release that should revolve the Error...I found that the 2P1 inverter had shut down at 8:50 AM and was showing an F80 CAN fault while, the 2P2 inverter continued to charge the batteries beyond the target I had set, and all the way back toward 100%. When I found the inverter shut down, the SOC was already at 92%, way above what I had set in the program.There are 3 key pieces that have to get straight in order for the 6500's to talk successfully to the LL v2's. 1. Updated 6500's firmware. 2. CORRECT LLv2 dip switches. Master to 0001, and slaves to unique numbers other than 0001. 3.(EG4 6500ex?) Thread starter SirSelrahc; Start date Sep 13, 2022; S. SirSelrahc New Member. Joined Sep 13, 2022 Messages 4. Sep 13, 2022 #1 Can the EG4 inverters do Grid Tie with Limiter (no feeding grid) functionality? I have been looking at the blue no-name blue grid tie inverters that have power limiting features.... it uses a clamp around ...I have EG4 6500EX inverters and when solar power ramps up to about 2KW+ coming in the fans really howl. You wouldn't want to be in the same room with them for very long. ... The two Growatt inverters have the 37 460W panels attached and that is going into the AC Coupled portion of the Sol-Ark 15K. The 550W panels connect directly to the Sol-Ark ...

Fo76 meat week rewards.

Shangri la massage seattle.

Jan 28, 2023. #8. Skypower said: In SBU mode the inverters will run on Solar, then Battery. When Solar is insufficient and Battery reaches back to grid setting (pgm12) it will switch to grid for load AND charge battery. You need to be sure that you don't exceed maximum input current (load + charge).Oct 2, 2023. #1. Got the chargeverter in. Was charging at 70 amps, up to 56.4v. Turned on the two inverters, it did it's poweron thing, then just as they were about to output, one of them immediately popped the battery breaker for it, 100A. Also, tripped off one of the three lifepower4s. It's reading a dead short on the battery terminals to it ...EG4® LL Firmware Update Cable. usb_serial_converter_ch340_windows_x64_drivers-20231101T152158Z-001. zip. Download.2 new in box (refurbished) EG4 6500ex inverters. These are two extra inverters I have, and no longer need because I sold my property. These have been certified by and sent to me from signature solar. $750 each or $1400 for the pair. I am willing to meet.. cash or zelle only Thanks post id: 7728203904.So EG4 released their latest firmware update for the 6500 inverters, 79.71 which gives you the ability to control the ground/neutral bond relay using the men...Inverter: https://signaturesolar.com/eg4-6-5k-off-grid-inverter-6500ex-48-a/?ref=bkpkbxdeBatteries: https://signaturesolar.com/eg4-lifepower4-lithium-battery...25 Oct 2022 ... today to update how my wiring is run from the inverters and take over one of my existing breaker panels in my home with my 2 EG4 6500EX-48 ...Our team has reviewed your ticket information and we see that the damage to your 1 x EG4 6.5kW Off-Grid Inverter | 6500EX-48 | 6500W Output | 8000W PV Input | 500V VOC Input | UL 1741 Certified | All in One Solar Inverter does not fall within Signature Solars warranty guidelines. We also understand that accidents happen and would like to offer ...I wanted to go over some features that I really haven't heard many people talk about. I'm guessing that like me, other people when reviewing the manual skip...Brexit is not the only big issue that is getting kicked down the road, with the reckoning over Tesla's looming debt issues, rising oil prices and the fallout from the inverted ...EG4-6000ex vs EG4-6500ex. 6000ex REQUIRES 240V input from grid or generator. Shore and generator to a transfer switch then to 6000ex. 25a on each leg out. 7500w solar input. ... I have looked at the EG4 inverters and almost made the mistake of getting a 6000/240v inverter. The 6500 grid input is 120VAC and produces 120v single phase 54amp ... ….

Messages. 52. Nov 24, 2022. #1. Thinking about getting EG4 6.5kW 6500EX-48 and pairing it with the EG4-LifePo4 5.12kWh battery with 1280W Solar (320W x 4 panels) and the grid AC input (120V input). Solar will be the priority and AC as the backup. I want to run a dishwasher, a 16cu refrigerator and clothes washer via the EG4 inverter.Oct 26, 2023 · Oct 26, 2023. #1. Most of us have probably seen Will’s review of the new EG4 6000xp by LuxPower. However, I have a few questions that weren’t quite clear to me. While the unit has surge capacity to 12kw, he said something about no surge capability on one leg only. While in use two 6500ex units now, one unit has the ability to surge well ... Brexit is not the only big issue that is getting kicked down the road, with the reckoning over Tesla's looming debt issues, rising oil prices and the fallout from the inverted ...EG4 6500EX-48 Off-Grid Inverter: https://signaturesolar.com/eg4-6-5k-off-grid-inverter-6500ex-48/EG4-LifePower4 LiFePO4 Battery: https://signaturesolar.com/e...Requesting - Off-Grid Inverter Experience 240V [Split-Phase] LV6548 / EG4 6.5K [6500EX-48] ... Setup is 2 - EG4 6500 ex inverters 4 - EG4 LiFePower battery’s I was wanting to run this system in split phase configuration, but …Hello. I just got my 2 WP eg4 48v batteries connected to my EG4 6.5 inverter and the panel strings hooked up. I've had lead acid and outback equipment for 17 years so this is a big switch! I used to have 3 muffin fans positioned for extra cooling. They were connected to the charge controllers and came on when float voltage was hit. 6500 ...I am also planning to do a firmware update but want to avoid the issues everyone else is experiencing. I had 1-6500ex 48 RMA'd through SS a year ago and that one is running 79.60 the other is 61.06. They keep changing settings periodically. ... I have two EG4 6500 EX inverters that have been working very well in parallel for the past 6 months. ...Need recommendations for an inverter to go with Trophy 6500ex battery. Prefer 50 amp and 12vdc outputs . B. BentleyJ Solar Wizard. Joined Jan 13, 2022 Messages ... Cool inverter with very similar transfer switch optimized for 50A RVs. ... EG4 18kPv and Generac Pwrcell Solar Inverter Compatibility. nateb; Apr 18, 2024 ...9. Jul 20, 2022. #1. I am planning to use only 120 V appliances in my cabin and I purchased one EG4 6500EX-48 for this purpose. This inverter will be connected directly to my main load panel and I have questions about this simple layout. The inverter and main panel will be located only 3 feet apart. Thank you for your assistance!EG4 6500 User Manual. Solar inverter/charger 6.5kva 120v ac. 1. Table Of Contents. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. Eg4 6500ex inverter, The EG4 8k Hybrid Inverter combines the functionality of a grid-tied and an off-grid system together while also eliminating the need for charge controllers or transformers to create a convenient, independent, all-purpose powerhouse! ... EG4® 6500EX-48 All-In-One Off-Grid Inverter [Legacy Product] 8kW Solar Input | 6.5kW AC Output 48V Battery ..., Thank you for your time and patience throughout this process! Our team has reviewed your ticket information and we see that you're experiencing issues with your 2x EG4 6.5kW Off-Grid Inverter | 6500EX-48 | 6500W Output | 8000W PV Input | 500V VOC Input | UL 1741 Certified | All in One Solar Inverter., Signature Solar is proud to partner with EG4 Electronics in unveiling the TUV Certified EG4 6500EX-48 Inverter. This inverter is designed to the high specifications to …, I never programmed the Modus interface for the EG4-6500EX by myself (I've only studied the Modbus spec of the EG4-6500EX). I just use SA to do the Modbus communication with the inverters and batteries. My smart home (OpenHAB) communicates via MQTT with SA and SA converts these MQTT messages to Modbus protocol., Need recommendations for an inverter to go with Trophy 6500ex battery. Prefer 50 amp and 12vdc outputs . B. BentleyJ Solar Wizard. Joined Jan 13, 2022 Messages ... Cool inverter with very similar transfer switch optimized for 50A RVs. ... EG4 18kPv and Generac Pwrcell Solar Inverter Compatibility. nateb; Apr 18, 2024 ..., Feb 15, 2023. #161. Tom Funchess said: I had that happen with my EG4 6500s - when I updated the firmware on the old inverter (May 2022) and the new inverter (November 2022 replacement) at the same time, the old inverter showed firmware 79.02 and the new inverter showed 79.03. I repeated the update 3 times and it never got the same version on ..., Use the provided communications cable to connect the host battery to the host inverter. Pins 1& 2 go to the battery and pins 3 & 5 go to the inverter. Then use the short patch communications cable to interconnect the remaining batteries. Set the host inverter program setting 14 to EG4. If there are slave inverters, set them to USE., From what others have mentioned on the EG4 6000 load test thread, is that it is basically a somewhat updated version of the MPP Solar LVX6048. Updated in that the PV voltage has been upped from 6kW to 7.5kW, …, LV6548 on Steriods: EG4 6500EX. Now imagine taking the LV6548 and making it better: It has double the PV input voltage, so you do not need a combiner box. ... If you would like to purchase the EG4 all-in-one inverter, click here If you would like to purchase a budget EG4 Server rack battery that communicates with this inverter, click here ..., Discover solar simplicity with the EG4 Load Center PDP. Effortlessly integrating PV disconnects, battery breakers, and AC input & output, this all-in-one unit makes paralleling 2 x EG4 6500EX inverters simple and easy. No need for separate DC components; the PDP has it all covered. Save time and money with this pre-wired powerhouse, perfect for ..., After trying for quite a while, I finally have reliable communication between SolarAssistant (SA) and all inverters and batteries. My setup: 6x EG4-6500EX-48 inverters in split phase. 3 inverters per phase; all manufactured in 09/2022; firmware (stationary) updated in all inverters to versions DSP=79.63 and MCU=61.12, 18 Feb 2023 ... Did the replacement inverters from Signature Solar resolve the issues that I was having with my 6500 inverters? Let's dig in and find out., The inverters also constantly switch in and out of bypass mode until the F80 fault is thrown. We are a new home builder and have made a number of inverter purchases and am seeking refunds on all of them. ... EG4 6500ex and 6000ex flickering lights and firmware. EG4_Jarrett; Oct 31, 2023; Off-grid Inverters; 4 5 6. Replies 109 Views 6K. Feb 23 ..., Related Manuals for EG4 6500EX-48 Inverter EG4 6500 EX-48 User Manual 80 pages Solar inverter/charger 6.5kva 120vac, How do I wire a generator to a 4 eg4 6500ex inverters, split phase, off grid? 71naes; Feb 5, 2024; General Troubleshooting Help; Replies 1 Views 154. Feb 5, 2024. Adam De Lay. J. 4 EG4 6500ex flickering lights on low loads only. Jefits; Feb 5, 2024; Off-grid Inverters; Replies 2 Views 230. Feb 6, 2024. SignatureSolarJess., EG4 Inverter Installation Full System Wiring And Tips! Off Grid Solar! OUR SOLAR EQUIPMENT...CLICK HERE: https://www.signaturesolar.com/?ref=countrylivingexp..., the EG4 6500EX-48 is nice since it starts at 80 vdc [most start at 120 vdc] and it is not too heavy i could get by with a 3000 watt system but i would need to pay close attention what i'm doing. if i was charging at 2400 watts, the AC was on 300 watts steady [600-900 start up], cooking [induction plate or microwave] 800-1800 watts, tankless ..., So EG4 released their latest firmware update for the 6500 inverters, 79.71 which gives you the ability to control the ground/neutral bond relay using the men..., I wanted to try and do a little walkthrough on how to set up the WiFi and WatchPower app for the 6500s. I know the first time I attempted to do this, I had ..., After some quick online shopping, #4 copper THHN + conduit comes to about $1600, and 2-2-2-4 aluminum URD is about $475. Aluminum is looking attractive, but Signature Solar strongly recommends against using aluminum. Also, it looks like the EG4 6500 terminals might not be big enough for 2 AWG, and aren't rated for AL/CU., With the release of the latest firmware from EG4 (79.61), it's supposed to resolve some flickering light issues when you have PV power coming in to the inver..., If I use only one MPPT/input on a EG4 6500ex-48 will the inverter be able to use more than 4000w? Say I have 2 PV strings in parallel inputting to a single MPPT input (other MPPT input not used) and the array is 380 VMP and amps are 17a. That could be 6460 watts into a single MPPT without exceeding the volt or amp limits., With the described cables I've successfully flashed the firmware of 9 EG4-LL V2 batteries and 6 EG4-6500EX inverters, last week. Good luck! Last edited: Apr 3, 2023. Reactions: PunchySunshine and FilterGuy. S. shaggy745 New Member. Joined Nov 5, 2022 Messages 104. ... The special EG4-RJ45 inverter cable View attachment 144297, Aug 10, 2022. #1. Hi, I am building a system with two EG4 6500EX inverters with EG4 server rack batteries just as shown in one of your recent videos. However, I am tying to the grid also. I only have 1 cable coming in from the grid and am wondering how you would recommend splitting this so that each inverter has a grid power in connection., This is a combination of the official change log from EG4 as well as some additional notes regarding forum posts. Please let me know if you have any additions or changes to be made. U1 - EG4 DSP 79.02 2022.05.04 factory firmware 79.03..., Hello all, I have been running the EG4 6500ex for a couple of weeks now then all of a sudden it started showing 0 battery voltage. I have 4 valence 12volt batteries wired in series. ... Yes I am having the same issues with EG4 inverter ex 6000 and battery. Reactions: debron55. debron55 New Member. Joined May 4, 2020 Messages 47., 18 Feb 2023 ... Did the replacement inverters from Signature Solar resolve the issues that I was having with my 6500 inverters? Let's dig in and find out., Location. Texas. Sep 28, 2023. #1. I'm seeking the "mobile" firmware version for EG-4 6500EX-48 inverters. Seems the product pages got moved around and prior links 404, or don't have firmware links.. Old Product link (404) New Product Link (no firmware downloads) New Firmware page, no EG4-6500EX-48 Listed., This week I mounted the 200A AC service panel and wired up the AC output from my two EG4 inverters to the AC panel. My inverters will be connected in 180 deg..., The EG4 6500 EX-48 is a residential self-consumption, multi-functional inverter/charger. Combining the capabilities of an inverter, MPPT solar charger, and battery charger, the 6500EX-48 All-in-One Solar Inverter offers uninterrupted power support in a single package. Upgraded features compared to the competition include a 500VOC/8000W …, Solar panels > eg4 6500ex, 48v 280Ah Eve cell battery > ac out to Rv power plug > power watch dog > breaker box". On yours I would have checked from the "ac out" then the "Rv power plug" and so on down the stream. Unplug everything then plug in one at a time until the shock occurs also., Signature Solar is proud to partner with EG4 Electronics in unveiling the TUV Certified EG4 6500EX-48 Inverter. This inverter is designed to the high specifications to meet or exceed UL1741 and CSA C22.2 requirements, and has been engineered to meet all the features that we hear our customers want., Nov 4, 2023. #25. I've been searching the forum to see if I can connect the running pair of two 6500ex in split phase while having the charge inverter charging the battery bank and I have a smart shunt I would like to see measure the current in rush so I suppose I would connect the Chargeverter to the system side of the Victron 500amp smartshunt.