Biomed microdevice

Biomed Microdevices. 2012 Dec;14(6):1019-25. doi: 10.1007/s10544-012-9704-1. Authors Sunghoon Cho 1 , Sung Jun Park, Seong Young Ko, Jong-Oh Park, Sukho Park. Affiliation 1 School of Mechanical Systems Engineering, Chonnam National University, Gwangju, 500-757, Korea. PMID: 22976580 DOI ...

Biomed microdevice. Continuous glucose monitoring (CGM) has the potential to greatly improve diabetes management. The aim of this work is to show a proof-of-concept CGM device which performs minimally invasive and minimally delayed in-situ glucose sensing in the dermal interstitial fluid, combining the advantages of microneedle-based and commercially available CGM systems. The device is based on the integration ...

Jun 2, 2023 · Correction to: On-chip construction of a fully structured scaffold-free vascularized renal tubule. Yuntian Zhu. Zhengdi Shi. Chengpan Li. Correction. Published: 11 March 2023. Article: 9. Volume 25, issue 2 articles listing for Biomedical Microdevices.

The arrows point to the implanted microdevice; the dotted lines indicate the trajectory of the microdevice at implantation. Figure reproduced from ref. 3 , Macmillan Publishers Ltd. Full size imageFrom Biomed Microdevices, 26 with permission. Clinical Application: Hemorrhagic Shock. Hemorrhagic shock is an acute condition that can result from severe traumatic injuries associated with massive bleeding loss, which if not treated within seconds or minutes could result in permanent damage or death. In most cases, critical patients do …Biomedical Microdevices. Volumes and issues. Volume 20, issue 2. Search within journal. Search. Volume 20, issue 2, June 2018. 30 articles in this issue. An efficient method for CTCs screening with excellent operability by integrating Parsortix™-like cell separation chip and selective size amplificationBiomimetics is the interdisciplinary scientific field focused on the study and imitation of biological systems, with the aim of solving complex technological problems. In this paper, we present a new bio-inspired design for microneedles (MNs) and MN arrays, intended for rapidly coating the MNs with drug/vaccine. The biomimetic approach …3 thg 6, 2019 ... 나노과학기술대학원 구성원분들께 이대식 박사님의 `Biomedical microdevice technologies for point of care applications;design, fabrication, ...To our best knowledge, there are no non-invasive and painless means for the diagnosis and treatment of intestinal bleeding as of now, especially the segment of intestine that cannot be reached by endoscopy. We proposed an intelligent intestinal bleeding diagnosis and treatment capsule (IBDTC) system for the first time to diagnose and treat intestinal bleeding with low power consumption ...We first perfused a microdevice containing fixed endothelium that was pretreated with a physiologically relevant dose of TNF-α (5 ng/mL) (Damas et al. 1989; Kim et al. 2014; Schlitt et al. 2004) with whole blood from a healthy donor containing 0 to 100 μg/mL (clinical range ~1–10 μg/mL) (Mascelli et al. 1998) of the antiplatelet GP IIb ...

To find out more about publishing your work Open Access in Biomedical Microdevices, including information on fees, funding and licenses, visit our Open access publishing page.Mar 7, 2019 · Porous microneedles (MNs) are expected to be applied for diagnostic microfluidic devices such as blood glucose monitoring as they enable a pain-free penetration of human skin and the extraction of interstitial fluids. However, conventional microfluidic systems require additional steps to separate the liquid from a porous structure used for fluid extraction. In this study, we developed a ... 2.1 Microdevice design and fabrication. The microdevice contains two independent compartments (Fig. 1): a cell culture slide on the top and one lower compartment containing the culture medium.This latter compartment can have two configurations: one used during cell growth and the other for permeability studies, …The arrows point to the implanted microdevice; the dotted lines indicate the trajectory of the microdevice at implantation. Figure reproduced from ref. 3 , Macmillan Publishers Ltd. Full size imageDec 5, 2014 · Passive biomedical microdevices for drug delivery do not rely on an actuation mechanism or on monitoring for feedback. These devices are reservoir based, relying on mass transfer across a permeable membrane to deliver pharmaceutical drugs, the biodegradation of a hermetic membrane, or a unique reservoir structure to achieve controlled release. 13 thg 12, 2009 ... Biomedical microdevices include any miniaturized devices or systems for biomedical or biological applications, from simple sensors for ...The healthcare system relies widely on biochemical information obtained from blood sample extracted via hypodermic needles, despite the invasiveness and pain associated with this procedure. Therefore, an alternative micro-scale needle for minimally invasive blood sampling is highly desirable. Tradit …

The principle of the method we term “microBubble-activated Acoustophoretic Cell Sorting (BAACS)” is shown in Fig. 1. Briefly, microbubbles coated with specific antibody are mixed with the target cells in a suspension. After mixing, target cells attached with microbubbles are pumped through the microfluidic channel under a constant acoustic ...Mar 18, 2021 · Modular design of paper based switches for autonomous lab-on paper micro devices. Yashodeep Patil. Kevin Dotseth. Venumadhav Korampally. OriginalPaper. Published: 27 November 2020. Article: 1. Volume 23, issue 1 articles listing for Biomedical Microdevices. Biomedical Microdevices. Volumes and issues. Volume 17, issue 1. Search within journal. Search. Volume 17, issue 1, February 2015. 24 articles in this issue. Impedance …Several groups are developing different versions of a new class of leadless, permanently implanted electronic devices with a size and form factor that allows them to be injected into muscles (BIONs™). Their circuitry is protected from body fluids by thin-walled hermetic capsules made from rigid and brittle materials (glass or ceramic) that include …Nov 16, 2021 · Since its inaugural issue in 1998, Biomedical Microdevices grew under Dr. Ferrari’s leadership and developed for more than 20 years to become a reference journal in the field, which has contributed to shaping this field. One hundred and six (106) Issues comprising more than 1800 articles have been published so far. The PDMS microdevice wa … Polydimethylsiloxane (PDMS) is a well-known biocompatible polymer employed for many applications in the biomedical field. In this study, the biocompatibility and versatility of PDMS was tested setting up a microdevice devoted to the purification and analysis of nucleic acids.

Up deck up daily themed crossword.

Biomedical Microdevices presents unique scholarly papers which go through peer review by experts in the given subject area. The journal encourages submissions from the research community where attention will be on the innovativeness and the practical significance of the published work.The healthcare system relies widely on biochemical information obtained from blood sample extracted via hypodermic needles, despite the invasiveness and pain associated with this procedure. Therefore, an alternative micro-scale needle for minimally invasive blood sampling is highly desirable. Tradit …Microneedle (MN) is a key technology of the biomedical engineering field due to its capability of accessing the biological information in a minimally invasive manner. One of the huge demands for next-generation healthcare monitoring is continuous monitoring, especially of blood glucose concentration. For this, MN should be kept inserted into the human skin for a certain period of time ...1 thg 12, 2020 ... ... microdevice for the facile foodborne path ... Biomed Nanotech201391951196110.1166/jbn.2013.1701Google Scholar ...2.1 Design and fabrication of the flexible electrode array. The 32-channel flexible MEA was designed for studying ECoG signals from the brain surface of a rat. The recording area was 2.4 mm × 3.6 mm, consisting of thirty-two electrodes (electrode diameter: 100 µm) for simultaneous recording of ECoG signals. 50 µm wide metal lines with a minimum separation of 25 µm are designed to connect ...Several groups are developing different versions of a new class of leadless, permanently implanted electronic devices with a size and form factor that allows them to be injected into muscles (BIONs™). Their circuitry is protected from body fluids by thin-walled hermetic capsules made from rigid and brittle materials (glass or ceramic) that include …

Cell therapy is used to treat various diseases and to repair injuries. Cell delivery is a crucial process that delivers cells to target sites. Cells must be precisely delivered to a target site and the cells that are delivered must be localized to the target site to repair damaged tissue. For stem c …Ziaie Biomedical Microdevices Laboratory. Research in our group is centered on biomedical applications of MEMS (BioMEMS) and nanotechnology, including a variety of device and microsystems to address important clinical problems.Papers in all areas of biomedical microdevices will be considered, including but not limited to: Clinical diagnostics and Point-of-Care (POC) testing. Micro- and nano- technologies for cell culture and single-cell analysis. Biomedical microsensors and wearable monitors. Genomics, proteomics, and drug development.A self-contained, integrated, disposable, sample-to-answer, polycarbonate microfluidic cassette for nucleic acid-based detection of pathogens at the point of care was designed, constructed, and tested. The cassette comprises on-chip sample lysis, nucleic acid isolation, enzymatic amplification (poly …For a microdevice requiring 0.5 mW for function, the device can be powered at a depth of 4.6 cm in a field optimized in muscle tissue, compared with 1.2 cm in air.This paper introduces a disposable battery-driven heating system for loop-mediated isothermal DNA amplification (LAMP) inside a centrifugally-driven DNA purification platform (LabTube). We demonstrate LabTube-based fully automated DNA purification of as low as 100 cell-equivalents of verotoxin-producing Escherichia coli (VTEC) in water, milk and apple juice in a laboratory centrifuge, followed ...Jun 6, 2021 · Cytotoxicity and action mechanisms of polycyclic aromatic hydrocarbons by a miniature electrochemical detection system. Shi Zhou. Yi Xing. Dongmei Wu. OriginalPaper. Published: 25 March 2021. Article: 19. Volume 23, issue 2 articles listing for Biomedical Microdevices. Jun 2, 2023 · Organ-on-a-chip (OoC) devices require the precise control of various media. This is mostly done using several fluid control components, which are much larger than the typical OoC device and connected through fluidic tubing, i.e., the fluidic system is not integrated, which inhibits the system’s portability. Here, we explore the limits of fluidic system integration using off-the-shelf fluidic ... The combination of micro synthetic structures with bacterial flagella motors represents an actual trend for the construction of self-propelled micro-robots. The development of methods for fabrication of these bacteria-based robots is a first crucial step towards the realization of functional miniature and autonomous moving robots. We …The specific interests of the Journal include systems for neural stimulation and recording, bioseparation technologies such as nanofilters and electrophoretic equipment, miniaturized analytic and DNA identification systems, biosensors. Year. Impact Factor (IF) Total Articles. Total Cites. 2022 (2023 update) 2.8. -.Apr 8, 2019 · Biomedical Microdevices - Developing strategies to deliver the required dose of therapeutics into target tissues and cell populations within the body is a principal aim of controlled release and... Feb 25, 2014 · a Battery stability tests with a constant resistance and initial power output of 2.5 W. Power, the product of the measured voltage and current, is plotted over time. The CR-2 battery yields a constant power output (~ 1.5 W), whilst A23 and 4LR44 collapse after <10 min. b The heater of Revolver III consists of two SMD thick film resistors and an NTC thermistor as a temperature sensor.

We demonstrate an acoustic platform for micro-vortexing in disposable polymer microfluidic chips with small-volume (20 μl) reaction chambers. The described method is demonstrated for a variety of standard vortexing functions, including mixing of fluids, re-suspension of a pellet of magnetic beads collected by a magnet placed on the …

Biomedical Microdevices. Volumes and issues. Volume 19, issue 2. Search within journal. Search. Volume 19, issue 2, June 2017. 25 articles in this issue. A generic label-free microfluidic microobject sorter using a magnetic elastic diverter Authors (first, second and last of 4) Jiachen Zhang;Nov 28, 2009 · Flow cytometer is a powerful single cell analysis tool that allows multi-parametric study of suspended cells. Most commercial flow cytometers available today are bulky, expensive instruments requiring high maintenance costs and specially trained personnel for operation. Hence, there is a need to develop a low cost, portable alternative that will aid in making this powerful research tool more ... Biomed Microdevices. 2008 Apr;10(2):243-9. doi: 10.1007/s10544-007-9130-y. Authors Yuejun Kang 1 , Dongqing Li, Spyros A Kalams, Josiane E Eid. Affiliation 1 Department of Mechanical Engineering, Vanderbilt University, 2301 Vanderbilt Place, Nashville, TN 37235, USA. PMID: 17899384 DOI ...BMES 5714 / 671 Biomedical Microdevices The goal of this course is to build the foundation necessary for engineering research in micro- and nano- biotechnology. The course will be broken down into four major area: micro- and nano- fabrication techniques, the fundamentals of microfluidics, micro- and nano- particle manipulation, and engineering ...Mar 18, 2023 · This study proposed an efficient, low-cost, and hand-hold PCR microdevice based on water-cooling technology for nucleic acid amplification. The whole device is approximately 110 mm × 100 mm × 40 mm in size and 300 g in weight, which is about 63 times smaller than a commercial PCR device (e.g., T-100 Thermal Cycler, BIO-RAD, USA). Nov 16, 2022 · Both passive and active microfluidic chips are used in many biomedical and chemical applications to support fluid mixing, particle manipulations, and signal detection. Passive microfluidic devices are geometry-dependent, and their uses are rather limited. Active microfluidic devices include sensors or detectors that transduce chemical, biological, and physical changes into electrical or ... Traditional publishing model – published articles are made available to institutions and individuals who subscribe to Biomedical Microdevices or who pay to read specific articles. Open Access – when an article is accepted for publication, the author/s or funder/s pay an Article Processing Charge (APC).An innovative procedure for measuring blood pressure, with none of the disadvantages of current procedures, is proposed. A highly-flexible capacitive strain gauge has been designed to measure changes in the diameter of a blood vessel; such changes are indicative of blood pressure. The sensor is impl …

Brian ackley.

Tvtv cincinnati.

Traditional publishing model – published articles are made available to institutions and individuals who subscribe to Biomedical Microdevices or who pay to read specific articles. Open Access – when an article is accepted for publication, the author/s or funder/s pay an Article Processing Charge (APC). Biomedical Microdevices. Volumes and issues. Volume 22, issue 1. Search within journal. Search. Volume 22, issue 1, March 2020. 22 articles in this issue. Enzymatically functionalized polyaniline thin films produced with one-step electrochemical immobilization and its application in glucose and urea potentiometric biosensorsMicrofluidic devices are electrical/mechanical systems that offer the ability to work with minimal sample volumes, short reactions times, and have the possibility to perform massive parallel operations. An important application of microfluidics is blood rheology in microdevices, which has played a key role in recent developments of lab-on-chip devices for blood sampling and analysis. The most ...Jan 1, 2015 · Biomedical microdevices present a variety of key advantages for applications in health care owing to their (1) extremely small sizes providing minimally invasive procedures, (2) low power consumption, (3) batch fabrication processes with high reproducibility, and (4) low cost per device, in conjunction with their multiple functionalities and ... 2.1 Microdevice design and fabrication. The microdevice contains two independent compartments (Fig. 1): a cell culture slide on the top and one lower compartment containing the culture medium.This latter compartment can have two configurations: one used during cell growth and the other for permeability studies, …Biomedical Microdevices. Volumes and issues. Volume 11, issue 5. Search within journal. Search. Volume 11, issue 5, October 2009. 20 articles in this issue. Quantitative analysis of single bacterial chemotaxis using a linear concentration gradient microchannel Authors (first, second and last of 6)Apr 17, 2010 · A self-contained, integrated, disposable, sample-to-answer, polycarbonate microfluidic cassette for nucleic acid—based detection of pathogens at the point of care was designed, constructed, and tested. The cassette comprises on-chip sample lysis, nucleic acid isolation, enzymatic amplification (polymerase chain reaction and, when needed, reverse transcription), amplicon labeling, and ... Dec 5, 2014 · Passive biomedical microdevices for drug delivery do not rely on an actuation mechanism or on monitoring for feedback. These devices are reservoir based, relying on mass transfer across a permeable membrane to deliver pharmaceutical drugs, the biodegradation of a hermetic membrane, or a unique reservoir structure to achieve controlled release. ….

2.1 Design and fabrication. The microfluidic co-culture platform is composed of two cell culture compartments, one for neuron cells and the other for OL cells. The two compartments are connected by arrays of 15–30 µm wide, 2.5 µm high microchannels ( n = 140–180). Typical sizes of embryonic cortical neuron cells isolated from E16-18 rats ...Nov 22, 2018 · Bioelectronic microdevices are an emerging class of biomedical devices miniaturized at the scale of a millimeter or less, which promise new capabilities for monitoring and treating human disease. Although rapid progress has been made in the sensing and actuation capabilities of microdevices, a major technological challenge remains in the way that these devices are powered within the body. In ... Biomedical Microdevices. Volumes and issues. Volume 11, issue 5. Search within journal. Search. Volume 11, issue 5, October 2009. 20 articles in this issue. Quantitative analysis of single bacterial chemotaxis using a linear concentration gradient microchannel Authors (first, second and last of 6)Rosemary L. Smith, University of Maine, Orono, ME, USA. Rosemary Smith graduated from the University of Rhode Island with a BS degree in Electrical Engineering, and from the University of Utah with a PhD in Bioengineering. Her research applies micro and nanoscale materials and technology to realize new or improved sensors, actuators, biomedical ... The fabrication of a micro-needle array and the cell transplantation process. a) two-stage micro-molding: PMMA solution is poured into the PDMS mold until it is 2/3 full and cured for 10 min and then more PMMA solution is added to fill the mold and the whole is cured overnight; b) Cell transplantation process: cells are loaded onto the micro-needle …The advancement of sample preparation techniques is essential for the field of cell-based therapeutics. To obtain cells suited for clinical applications, the entire process starting from acquiring donor tissue biopsy, all through cell transplantation into the recipient, should occur in an integrated, safe, and efficient system. The current laboratory approach for solid tissue-to-cell isolation ...We envision Biomedical Microdevices to transform into the main platform for publishing the latest scientific and engineering discoveries, for leading experts in the field to provide their prospective on where the field is moving to, and where rising star researchers can present their cutting-edge advances. ... Biomed Microdevices 24, 1 (2022 ...Modular design of paper based switches for autonomous lab-on paper micro devices. Yashodeep Patil. Kevin Dotseth. Venumadhav Korampally. OriginalPaper. Published: 27 November 2020. Article: 1. Volume 23, issue 1 articles listing for Biomedical Microdevices. Biomed microdevice, Biomed Microdevices. 2008 Dec;10(6):909. doi: 10.1007/s10544-008-9206-3. ... A cell concentration microdevice for immunomagnetic pathogen isolation from a dilute sample is presented. Cells are driven by integrated on-chip pumps through a fluidized bed of immobilized immunomagnetic beads. Off-chip polymerase chain reaction and capillary ..., Reliable long-term cell culture in microfluidic system is limited by air bubble formation and accumulation. In this study, we developed a bubble removal system capable of both trapping and discharging air bubbles in a consistent and reliable manner. Combined with PDMS (Polydimethylsiloxane) hydrophi …, May 18, 2020 · Sepsis, a life-threatening organ dysfunction caused by a dysregulated host response, leads the U.S in both mortality rate and cost of treatment. Sepsis treatment protocols currently rely on broad and non-specific parameters like heart and respiration rate, and temperature; however, studies show that biomarkers Interlukin-6 (IL-6) and Procalcitonin (PCT) correlate to sepsis progression and ... , Apr 4, 2023 · The complex, dynamic environment of the human lower gastrointestinal tract is colonized by hundreds of bacterial species that impact health and performance. Ex vivo study of the functional interactions between microbial community members in conditions representative of those in the gut is an ongoing challenge. We have developed an in vitro 40-plex platform that provides an oxygen gradient to ... , Physiological and morphological properties of the human intestine cannot be accurately mimicked in conventional culture devices such as well plates and petri dishes where intestinal epithelial cells form a monolayer with loose contacts among cells. Here, we report a novel microfluidic cell culture device (μFCCD) that can be used to …, Isolation of exosome from the culture medium of Nasopharyngeal cancer (NPC) C666-1 cells using inertial based Microfluidic channel. Boon Yew Teoh. Yang Mooi Lim. Poh Foong Lee. OriginalPaper. Published: 26 January 2022. Article: 12., Design and performance evaluation of collision protection-based safety operation for a haptic robot-assisted catheter operating system. Linshuai Zhang. Shuxiang Guo. Hidenori Ishihara. OriginalPaper. Published: 23 February 2018. Article: 22. Volume 20, issue 2 articles listing for Biomedical Microdevices., Jun 6, 2021 · Cytotoxicity and action mechanisms of polycyclic aromatic hydrocarbons by a miniature electrochemical detection system. Shi Zhou. Yi Xing. Dongmei Wu. OriginalPaper. Published: 25 March 2021. Article: 19. Volume 23, issue 2 articles listing for Biomedical Microdevices. , Bangkok is located on the delta of the Chao Phraya River, about 25 miles (40 km) from the Gulf of Thailand.It was formerly divided into two municipalities—Krung Thep on the east bank and Thon Buri on the west—connected by several bridges. In 1971 the two were united as a city-province with a single municipal government.In 1972 the city and the two surrounding provinces were merged into one ..., Biomedical Microdevices is a Transformative Journal (TJ). Once the article is accepted for publication, authors will have the option to choose how their article is published: Traditional …, Biomedical Microdevices covers research in the diagnostic and therapeutic applications of Micro-Electro-Mechanical Systems, microfabrication, and nanotechnology. …, Biomed Microdevice 21:72. Article Google Scholar Lacina K, Skládal P, James TD (2014) Boronic acids for sensing and other applications—a mini-review of papers published in 2013. Chem Cent J 8:60. Article Google Scholar Law JWF, Mutalib NSA, Chan KG, Lee LH (2014) Rapid methods for the detection of foodborne bacterial pathogens: …, Jun 30, 2022 · Dielectric properties of a cell are biophysical properties of high interest for various applications. However, measuring these properties accurately is not easy, which can be exemplified by the large variations in reported dielectric properties of the same cell types. This paper presents a method for measuring the dielectric properties of cells at high frequency, especially lipid-producing ... , Multiplex detection is a smart and an emerging approach in point-of-care testing as it reduces analysis time and testing cost by detecting multiple analytes or biomarkers simultaneously which are crucial for disease detection at an early stage. Application of inexpensive substrate such as paper has immense potential and matter of research interest in the area of point of care testing for ..., From Biomed Microdevices, 26 with permission. Clinical Application: Hemorrhagic Shock. Hemorrhagic shock is an acute condition that can result from severe traumatic injuries associated with massive bleeding loss, which if not treated within seconds or minutes could result in permanent damage or death. In most cases, critical patients do …, He hopes to earn his MS in Biomedical Engineering and his MS in Applied Cognition and Neuroscience within the next 2-3 years, after which he would like to attend a PhD program which merges his two passions: engineering and neuroscience. Erik graduated with a dual degree (BS in Neuroscience and BA in Psychology) from UTD in the Spring of 2011 ..., ... Biomed. Microdevice., 767-780 (2013). 語言, 中文. 列印本頁. RulingDigital. 國立清華大學化學工程學系請詳見使用規則|聯絡我們。 地址:國立清華大學化學工程學系新竹 ..., Further area of research is 3D-manufactured microencapsulation devices for the transplantation of endocrine cells. The primary focus is the creation of a protected environment supporting cell …, 2.4 Glioblastoma adhesion on statically cultured endothelium. In a static adhesion experiment, glass bottoms of 8-well chambered slides (Lab-tek II, Nunc, USA) were coated with 10 μ g mL − 1 of human plasma fibronectin (Invitrogen, USA). HUVEC cells of 1 × 10 5 were seeded in each well and allowed to adhere for 24 h., As the BioMEMS field has matured, devices are increasing being developed as an active interface between the artificial microdevice and patients. ... Biomed Microdevices. 2007; 9 (4):435–42. doi: 10.1007/s10544-007-9047-5. [Google Scholar] 22. Fissell WH, Fleischman AJ, Humes HD, Roy S. Development of continuous implantable renal replacement ..., In contrast to traditional large-scale robots, which require complicated mechanical joints and material rigidity, microrobots made of soft materials have exhibited amazing features and great potential for extensive applications, such as minimally invasive surgery. However, microrobots are faced with energy supply and control issues due to the miniaturization. Magnetic field actuation emerges ..., The long- and thin-GRIN-lens-based microendoscope investigated here, which is attractive for biomedical applications, is being prioritized for use in a clinical stage microdevice that measures three-dimensional drug responses inside the body. ... Keywords: GRIN-lens microendoscopy; biomedical microdevice; in vivo drug response testing; two ..., Embryonic stem (ES) cell is of great interest cell source in regenerating tissue constructs. We hypothesized that the interaction of cell-extracellular matrices (ECMs) would enable the control of ES cell differentiation pathway. We fabricated the hydrogel microwell array system to regulate uniform-s …, Welcome to Biomedical Microdevice Lab in HKUST! We are in the pursuit of advanced microfluidic devices to address practical issues in life science and medicine. Our research interests primarily include siliconbased fabrication, nucleic acid analysis, patch clamp electrophysiology, electrokinetic-based separation, droplet microfluidics ..., Isolation of exosome from the culture medium of Nasopharyngeal cancer (NPC) C666-1 cells using inertial based Microfluidic channel. Boon Yew Teoh. Yang Mooi Lim. Poh Foong Lee. OriginalPaper. Published: 26 January 2022. Article: 12., Advanced Computational Methods and Modeling for Biomedical Applications 1: 3: BMES 5574: Advanced Biomaterials 1: 3: BMES 5614: Multiscale Cancer Engineering 1: 3: BMES 5714: Biomedical Microdevices 1: 3: BMES 5724: Biomedical Nanoengineering 1: 3: BMES 5764: Modeling MEMS and NEMS 1: 3: ESM 4105: Engineering Analysis of Physiologic Systems: 3 ... , Primary hepatocyte cultures have been used in studies on liver disease, physiology, and pharmacology. While they are an important tool for in vitro liver studies, maintaining liver-specific characteristics of hepatocytes in vitro is difficult, as these cells rapidly lose their unique characteristics and functions. Portal flow is an important …, In addition, clinical conditions that require a combination of drugs with specific pharmacodynamic profiles and local delivery will benefit from drug delivery microdevices. This review provides a summary of various clinical applications for state-of-the-art controlled drug delivery microdevices, including cancer, endocrine and ocular disorders ..., The specific interests of the Journal include systems for neural stimulation and recording, bioseparation technologies such as nanofilters and electrophoretic equipment, miniaturized analytic and DNA identification systems, biosensors. Year. Impact Factor (IF) Total Articles. Total Cites. 2022 (2023 update) 2.8. -., The Biomedical Microdevices discipline seeks to leverage phenomena at the micro- and nanoscale to solve problems in medicine and biology. This area includes lab-on-a-chip …, Polydimethylsiloxane (PDMS) is a well-known biocompatible polymer employed for many applications in the biomedical field. In this study, the biocompatibility and versatility of …, In Microdevice 2 (Fig. 2(b)), on the other hand, split-flows from the main stream are re-injected through the 40 loop channels (20 μm in width), which act as the flow without cells in the case of Microdevice 1. Approximately 50% of the introduced liquid flow will be split into the 40 loop channels when the channel depth is 30 μm, and re-injected …, Biomedical Microdevices. Volumes and issues. Volume 19, issue 2. Search within journal. Search. Volume 19, issue 2, June 2017. 25 articles in this issue. A generic label-free microfluidic microobject sorter using a magnetic elastic diverter Authors (first, second and last of 4) Jiachen Zhang;